SHS · EN 10219 · cold formed

SHS 60/6

SHS 60/6 is a cold-formed square hollow section per EN 10219: side 60 mm, wall thickness 6 mm, weight 9.5 kg/m, cross-section area 12 cm², moment of inertia Iy = 56.1 cm⁴, elastic section modulus Wel,y = 18.7 cm³.

Cross section · mm
yz60606[mm]
60Side a · mm
6Wall thickness t · mm
12.03Area A · cm²
9.45Mass G · kg/m
Geometry
Side dimension60.00 mm
Wall thickness t6.00 mm
Outer corner radius ro12.00 mm
Inner corner radius ri6.00 mm
Cross-section area A12.030 cm²
Weight G
steel 7850 kg/m³
9.45kg/m
Section properties
I56.070 cm⁴
Wel18.690 cm³
Wpl23.680 cm³
i21.60 mm
It98.410 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of SHS 60/6 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 6.5 kN·m
Shear/ 95.5 kN
Compression/ 39.0 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl6.5 kN·m / 6.5 kN·m
Vc,z,Rd / Vc,y,RdA_v = 602 mm²95.5 kN / 95.5 kN
Npl,Rd / Nb,Rd330.8 kN / 39.0 kN
Ncr,y / Ncr,z46.5 kN / 46.5 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.12

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.