SHS · EN 10219 · cold formed

SHS 30/3

SHS 30/3 is a cold-formed square hollow section per EN 10219: side 30 mm, wall thickness 3 mm, weight 2.4 kg/m, cross-section area 3 cm², moment of inertia Iy = 3.5 cm⁴, elastic section modulus Wel,y = 2.3 cm³.

Cross section · mm
yz30303[mm]
30Side a · mm
3Wall thickness t · mm
3.01Area A · cm²
2.36Mass G · kg/m
Geometry
Side dimension30.00 mm
Wall thickness t3.00 mm
Outer corner radius ro6.00 mm
Inner corner radius ri3.00 mm
Cross-section area A3.010 cm²
Weight G
steel 7850 kg/m³
2.36kg/m
Section properties
I3.504 cm⁴
Wel2.336 cm³
Wpl2.959 cm³
i10.80 mm
It6.150 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of SHS 30/3 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 0.8 kN·m
Shear/ 23.9 kN
Compression/ 2.7 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl0.8 kN·m / 0.8 kN·m
Vc,z,Rd / Vc,y,RdA_v = 151 mm²23.9 kN / 23.9 kN
Npl,Rd / Nb,Rd82.8 kN / 2.7 kN
Ncr,y / Ncr,z2.9 kN / 2.9 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.03

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.