SHS · EN 10219 · cold formed

SHS 220/10

SHS 220/10 is a cold-formed square hollow section per EN 10219: side 220 mm, wall thickness 10 mm, weight 63.2 kg/m, cross-section area 80.6 cm², moment of inertia Iy = 5782 cm⁴, elastic section modulus Wel,y = 525.7 cm³.

Cross section · mm
yz22022010[mm]
220Side a · mm
10Wall thickness t · mm
80.57Area A · cm²
63.20Mass G · kg/m
Geometry
Side dimension220.00 mm
Wall thickness t10.00 mm
Outer corner radius ro25.00 mm
Inner corner radius ri15.00 mm
Cross-section area A80.570 cm²
Weight G
steel 7850 kg/m³
63.20kg/m
Section properties
I5 782.000 cm⁴
Wel525.700 cm³
Wpl624.600 cm³
i84.70 mm
It9 533.000 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of SHS 220/10 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 171.8 kN·m
Shear/ 639.6 kN
Compression/ 1.63 MN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl171.8 kN·m / 171.8 kN·m
Vc,z,Rd / Vc,y,RdA_v = 4029 mm²639.6 kN / 639.6 kN
Npl,Rd / Nb,Rd2.22 MN / 1.63 MN
Ncr,y / Ncr,z4.79 MN / 4.79 MN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.74

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.