SHS · EN 10219 · cold formed

SHS 90/6

SHS 90/6 is a cold-formed square hollow section per EN 10219: side 90 mm, wall thickness 6 mm, weight 15.1 kg/m, cross-section area 19.2 cm², moment of inertia Iy = 220.5 cm⁴, elastic section modulus Wel,y = 49 cm³.

Cross section · mm
yz90906[mm]
90Side a · mm
6Wall thickness t · mm
19.23Area A · cm²
15.10Mass G · kg/m
Geometry
Side dimension90.00 mm
Wall thickness t6.00 mm
Outer corner radius ro12.00 mm
Inner corner radius ri6.00 mm
Cross-section area A19.230 cm²
Weight G
steel 7850 kg/m³
15.10kg/m
Section properties
I220.500 cm⁴
Wel48.990 cm³
Wpl59.540 cm³
i33.90 mm
It367.800 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of SHS 90/6 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 16.4 kN·m
Shear/ 152.7 kN
Compression/ 136.2 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl16.4 kN·m / 16.4 kN·m
Vc,z,Rd / Vc,y,RdA_v = 962 mm²152.7 kN / 152.7 kN
Npl,Rd / Nb,Rd528.8 kN / 136.2 kN
Ncr,y / Ncr,z182.8 kN / 182.8 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.26

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.