RHS · EN 10219 · cold formed

RHS 90×50/3

RHS 90×50/3 is a cold-formed rectangular hollow section per EN 10219: height 90 mm, width 50 mm, wall thickness 3 mm, weight 6.1 kg/m, cross-section area 7.8 cm², moment of inertia Iy = 81.9 cm⁴, elastic section modulus Wel,y = 18.2 cm³.

Cross section · mm
yz50903[mm]
90Height h · mm
50Width b · mm
7.81Area A · cm²
6.13Mass G · kg/m
Geometry
Height h90.00 mm
Width b50.00 mm
Wall thickness t3.00 mm
Outer corner radius ro6.00 mm
Inner corner radius ri3.00 mm
Cross-section area A7.810 cm²
Weight G
steel 7850 kg/m³
6.13kg/m
Section properties
I81.850 cm⁴32.740 cm⁴
Wel18.190 cm³13.100 cm³
Wpl22.600 cm³15.030 cm³
It76.670 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 90×50/3 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 6.2 kN·m
Shear/ 79.7 kN
Compression/ 23.0 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl6.2 kN·m / 4.1 kN·m
Vc,z,Rd / Vc,y,RdA_v = 502 mm²79.7 kN / 44.3 kN
Npl,Rd / Nb,Rd214.8 kN / 23.0 kN
Ncr,y / Ncr,z67.9 kN / 27.1 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.11

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.