RHS · EN 10219 · cold formed

RHS 90×50/2.5

RHS 90×50/2.5 is a cold-formed rectangular hollow section per EN 10219: height 90 mm, width 50 mm, wall thickness 2.5 mm, weight 5.2 kg/m, cross-section area 6.6 cm², moment of inertia Iy = 70.3 cm⁴, elastic section modulus Wel,y = 15.6 cm³.

Cross section · mm
yz50902.5[mm]
90Height h · mm
50Width b · mm
6.59Area A · cm²
5.17Mass G · kg/m
Geometry
Height h90.00 mm
Width b50.00 mm
Wall thickness t2.50 mm
Outer corner radius ro5.00 mm
Inner corner radius ri2.50 mm
Cross-section area A6.590 cm²
Weight G
steel 7850 kg/m³
5.17kg/m
Section properties
I70.260 cm⁴28.240 cm⁴
Wel15.610 cm³11.290 cm³
Wpl19.250 cm³12.820 cm³
It65.300 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 90×50/2.5 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 5.3 kN·m
Shear/ 67.3 kN
Compression/ 19.8 kN
Class1 / 2bending / compression
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl5.3 kN·m / 3.5 kN·m
Vc,z,Rd / Vc,y,RdA_v = 424 mm²67.3 kN / 37.4 kN
Npl,Rd / Nb,Rd181.2 kN / 19.8 kN
Ncr,y / Ncr,z58.2 kN / 23.4 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.11

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.