RHS · EN 10219 · cold formed

RHS 300×200/12.5

RHS 300×200/12.5 is a cold-formed rectangular hollow section per EN 10219: height 300 mm, width 200 mm, wall thickness 12.5 mm, weight 88 kg/m, cross-section area 112 cm², moment of inertia Iy = 13180 cm⁴, elastic section modulus Wel,y = 878.6 cm³.

Cross section · mm
yz20030012.5[mm]
300Height h · mm
200Width b · mm
112.04Area A · cm²
88.00Mass G · kg/m
Geometry
Height h300.00 mm
Width b200.00 mm
Wall thickness t12.50 mm
Outer corner radius ro37.50 mm
Inner corner radius ri25.00 mm
Cross-section area A112.040 cm²
Weight G
steel 7850 kg/m³
88.00kg/m
Section properties
I13 180.000 cm⁴7 060.000 cm⁴
Wel878.600 cm³706.000 cm³
Wpl1 091.000 cm³827.900 cm³
It15 770.000 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 300×200/12.5 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 300.0 kN·m
Shear/ 1.07 MN
Compression/ 2.18 MN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl300.0 kN·m / 227.7 kN·m
Vc,z,Rd / Vc,y,RdA_v = 6722 mm²1.07 MN / 711.5 kN
Npl,Rd / Nb,Rd3.08 MN / 2.18 MN
Ncr,y / Ncr,z10.93 MN / 5.85 MN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.71

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.