RHS · EN 10219 · cold formed

RHS 200×100/12.5

RHS 200×100/12.5 is a cold-formed rectangular hollow section per EN 10219: height 200 mm, width 100 mm, wall thickness 12.5 mm, weight 48.7 kg/m, cross-section area 62 cm², moment of inertia Iy = 2659 cm⁴, elastic section modulus Wel,y = 265.9 cm³.

Cross section · mm
yz10020012.5[mm]
200Height h · mm
100Width b · mm
62.04Area A · cm²
48.70Mass G · kg/m
Geometry
Height h200.00 mm
Width b100.00 mm
Wall thickness t12.50 mm
Outer corner radius ro37.50 mm
Inner corner radius ri25.00 mm
Cross-section area A62.040 cm²
Weight G
steel 7850 kg/m³
48.70kg/m
Section properties
I2 659.000 cm⁴892.200 cm⁴
Wel265.900 cm³178.400 cm³
Wpl359.100 cm³220.800 cm³
It2 474.000 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 200×100/12.5 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 98.8 kN·m
Shear/ 656.7 kN
Compression/ 526.4 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl98.8 kN·m / 60.7 kN·m
Vc,z,Rd / Vc,y,RdA_v = 4136 mm²656.7 kN / 328.3 kN
Npl,Rd / Nb,Rd1.71 MN / 526.4 kN
Ncr,y / Ncr,z2.20 MN / 739.7 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.31

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.