RHS · EN 10219 · cold formed

RHS 200×100/12

RHS 200×100/12 is a cold-formed rectangular hollow section per EN 10219: height 200 mm, width 100 mm, wall thickness 12 mm, weight 47.1 kg/m, cross-section area 60.1 cm², moment of inertia Iy = 2607 cm⁴, elastic section modulus Wel,y = 260.7 cm³.

Cross section · mm
yz10020012[mm]
200Height h · mm
100Width b · mm
60.06Area A · cm²
47.10Mass G · kg/m
Geometry
Height h200.00 mm
Width b100.00 mm
Wall thickness t12.00 mm
Outer corner radius ro36.00 mm
Inner corner radius ri24.00 mm
Cross-section area A60.060 cm²
Weight G
steel 7850 kg/m³
47.10kg/m
Section properties
I2 607.000 cm⁴875.600 cm⁴
Wel260.700 cm³175.100 cm³
Wpl350.000 cm³215.300 cm³
It2 414.000 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 200×100/12 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 96.3 kN·m
Shear/ 635.7 kN
Compression/ 515.0 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl96.3 kN·m / 59.2 kN·m
Vc,z,Rd / Vc,y,RdA_v = 4004 mm²635.7 kN / 317.9 kN
Npl,Rd / Nb,Rd1.65 MN / 515.0 kN
Ncr,y / Ncr,z2.16 MN / 725.9 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.31

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.