RHS · EN 10210 · hot finished

RHS 90×50/4

RHS 90×50/4 is a hot-finished rectangular hollow section per EN 10210: height 90 mm, width 50 mm, wall thickness 4 mm, weight 8.2 kg/m, cross-section area 10.4 cm², moment of inertia Iy = 107.1 cm⁴, elastic section modulus Wel,y = 23.8 cm³.

Cross section · mm
yz50904[mm]
90Height h · mm
50Width b · mm
10.39Area A · cm²
8.15Mass G · kg/m
Geometry
Height h90.00 mm
Width b50.00 mm
Wall thickness t4.00 mm
Outer corner radius ro6.00 mm
Inner corner radius ri4.00 mm
Cross-section area A10.390 cm²
Weight G
steel 7850 kg/m³
8.15kg/m
Section properties
I107.100 cm⁴41.950 cm⁴
Wel23.800 cm³16.780 cm³
Wpl29.850 cm³19.630 cm³
It97.520 cm⁴
Reference
Profile standardEN 10210
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 90×50/4 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 8.2 kN·m
Shear/ 106.0 kN
Compression/ 32.3 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl8.2 kN·m / 5.4 kN·m
Vc,z,Rd / Vc,y,RdA_v = 668 mm²106.0 kN / 58.9 kN
Npl,Rd / Nb,Rd285.7 kN / 32.3 kN
Ncr,y / Ncr,z88.8 kN / 34.8 kN
fyEN 10210-1275 MPa
γM0 / γM11.00 / 1.00
Curve a · χ0.11

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.