RHS · EN 10210 · hot finished

RHS 200×100/10

RHS 200×100/10 is a hot-finished rectangular hollow section per EN 10210: height 200 mm, width 100 mm, wall thickness 10 mm, weight 43.1 kg/m, cross-section area 54.9 cm², moment of inertia Iy = 2664 cm⁴, elastic section modulus Wel,y = 266.4 cm³.

Cross section · mm
yz10020010[mm]
200Height h · mm
100Width b · mm
54.93Area A · cm²
43.10Mass G · kg/m
Geometry
Height h200.00 mm
Width b100.00 mm
Wall thickness t10.00 mm
Outer corner radius ro15.00 mm
Inner corner radius ri10.00 mm
Cross-section area A54.930 cm²
Weight G
steel 7850 kg/m³
43.10kg/m
Section properties
I2 664.000 cm⁴868.800 cm⁴
Wel266.400 cm³173.800 cm³
Wpl340.900 cm³206.200 cm³
It2 156.000 cm⁴
Reference
Profile standardEN 10210
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 200×100/10 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 93.7 kN·m
Shear/ 581.4 kN
Compression/ 596.9 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl93.7 kN·m / 56.7 kN·m
Vc,z,Rd / Vc,y,RdA_v = 3662 mm²581.4 kN / 290.7 kN
Npl,Rd / Nb,Rd1.51 MN / 596.9 kN
Ncr,y / Ncr,z2.21 MN / 720.3 kN
fyEN 10210-1275 MPa
γM0 / γM11.00 / 1.00
Curve a · χ0.40

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.