LU · EN 10056-1

L 70×50/6

L 70×50/6 is an unequal-leg steel angle per EN 10056-1: legs 70×50 mm, thickness 6 mm, weight 5.4 kg/m, cross-section area 6.9 cm², moment of inertia Iy = 33.4 cm⁴, elastic section modulus Wel,y = 7 cm³.

Cross section · mm
yz7050612.522.3[mm]
70Long leg a · mm
50Short leg b · mm
6.89Area A · cm²
5.41Mass G · kg/m
Geometry
Long leg a70.00 mm
Short leg b50.00 mm
Thickness t6.00 mm
Root radius r₁7.00 mm
Cross-section area A6.890 cm²
Centroid Cx22.3 mm
Centroid Cy12.5 mm
Weight G
steel 7850 kg/m³
5.41kg/m
Section properties
Iy33.400 cm⁴
Iz14.200 cm⁴
Wel,y7.010 cm³
Wel,z3.780 cm³
iy22.00 mm
iz14.30 mm
Principal axes u–v
Iu39.700 cm⁴
Iv7.920 cm⁴
iv10.70 mm
tan α0.496 –
Reference
Profile standardEN 10056-1
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of L 70×50/6 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 1.9 kN·m
Shear/ 54.7 kN
Compression/ 6.2 kN
Class3
Resistances and factors
Mc,y,Rd / Mc,z,RdW_el1.9 kN·m / 1.0 kN·m
Vc,z,Rd / Vc,y,RdA_v = 345 mm²54.7 kN / 54.7 kN
Npl,Rd / Nb,Rd189.5 kN / 6.2 kN
Ncr,y / Ncr,v27.7 kN / 6.6 kN
fyEN 10025-2275 MPa
γM0 / γM11.00 / 1.00
Curve b · χ0.03

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.

For angles the bending values refer to the axes parallel to the legs, which are not principal axes. A moment about one of them also bends the section about the other, so bending has to be resolved into the principal axes u and v and checked biaxially. Buckling already uses the weaker principal axis v.