LU · EN 10056-1

L 200×150/15

L 200×150/15 is an unequal-leg steel angle per EN 10056-1: legs 200×150 mm, thickness 15 mm, weight 39.6 kg/m, cross-section area 50.5 cm², moment of inertia Iy = 2020 cm⁴, elastic section modulus Wel,y = 147 cm³.

Cross section · mm
yz2001501537.362.1[mm]
200Long leg a · mm
150Short leg b · mm
50.50Area A · cm²
39.60Mass G · kg/m
Geometry
Long leg a200.00 mm
Short leg b150.00 mm
Thickness t15.00 mm
Root radius r₁15.00 mm
Cross-section area A50.500 cm²
Centroid Cx62.1 mm
Centroid Cy37.3 mm
Weight G
steel 7850 kg/m³
39.60kg/m
Section properties
Iy2 020.000 cm⁴
Iz979.000 cm⁴
Wel,y147.000 cm³
Wel,z86.900 cm³
iy63.30 mm
iz44.00 mm
Principal axes u–v
Iu2 480.000 cm⁴
Iv526.000 cm⁴
iv32.30 mm
tan α0.551 –
Reference
Profile standardEN 10056-1
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of L 200×150/15 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ —
Shear/ 400.9 kN
Compression/ —

Bending and compression are not available for class 4 sections; effective properties per EN 1993-1-5 are required.

Class4
Resistances and factors
Mc,y,Rd / Mc,z,Rd— / —
Vc,z,Rd / Vc,y,RdA_v = 2525 mm²400.9 kN / 400.9 kN
Npl,Rd / Nb,Rd— / —
Ncr,y / Ncr,v1.67 MN / 436.1 kN
fyEN 10025-2275 MPa
γM0 / γM11.00 / 1.00
Curve b · χ0.26

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.

For angles the bending values refer to the axes parallel to the legs, which are not principal axes. A moment about one of them also bends the section about the other, so bending has to be resolved into the principal axes u and v and checked biaxially. Buckling already uses the weaker principal axis v.