LU · EN 10056-1

L 100×75/10

L 100×75/10 is an unequal-leg steel angle per EN 10056-1: legs 100×75 mm, thickness 10 mm, weight 13 kg/m, cross-section area 16.6 cm², moment of inertia Iy = 162 cm⁴, elastic section modulus Wel,y = 23.8 cm³.

Cross section · mm
yz100751019.531.9[mm]
100Long leg a · mm
75Short leg b · mm
16.60Area A · cm²
13.00Mass G · kg/m
Geometry
Long leg a100.00 mm
Short leg b75.00 mm
Thickness t10.00 mm
Root radius r₁10.00 mm
Cross-section area A16.600 cm²
Centroid Cx31.9 mm
Centroid Cy19.5 mm
Weight G
steel 7850 kg/m³
13.00kg/m
Section properties
Iy162.000 cm⁴
Iz77.600 cm⁴
Wel,y23.800 cm³
Wel,z14.000 cm³
iy31.20 mm
iz21.60 mm
Principal axes u–v
Iu197.000 cm⁴
Iv42.200 cm⁴
iv15.90 mm
tan α0.544 –
Reference
Profile standardEN 10056-1
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of L 100×75/10 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 6.5 kN·m
Shear/ 131.8 kN
Compression/ 31.9 kN
Class3
Resistances and factors
Mc,y,Rd / Mc,z,RdW_el6.5 kN·m / 3.9 kN·m
Vc,z,Rd / Vc,y,RdA_v = 830 mm²131.8 kN / 131.8 kN
Npl,Rd / Nb,Rd456.5 kN / 31.9 kN
Ncr,y / Ncr,v134.3 kN / 35.0 kN
fyEN 10025-2275 MPa
γM0 / γM11.00 / 1.00
Curve b · χ0.07

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.

For angles the bending values refer to the axes parallel to the legs, which are not principal axes. A moment about one of them also bends the section about the other, so bending has to be resolved into the principal axes u and v and checked biaxially. Buckling already uses the weaker principal axis v.