RHS · EN 10219 · cold formed

RHS 300×150/6.3

RHS 300×150/6.3 is a cold-formed rectangular hollow section per EN 10219: height 300 mm, width 150 mm, wall thickness 6.3 mm, weight 42.2 kg/m, cross-section area 53.8 cm², moment of inertia Iy = 6266 cm⁴, elastic section modulus Wel,y = 417.7 cm³.

Cross section · mm
yz1503006.3[mm]
300Height h · mm
150Width b · mm
53.75Area A · cm²
42.20Mass G · kg/m
Geometry
Height h300.00 mm
Width b150.00 mm
Wall thickness t6.30 mm
Outer corner radius ro15.75 mm
Inner corner radius ri9.45 mm
Cross-section area A53.750 cm²
Weight G
steel 7850 kg/m³
42.20kg/m
Section properties
I6 266.000 cm⁴2 150.000 cm⁴
Wel417.700 cm³286.700 cm³
Wpl517.400 cm³320.900 cm³
It5 234.000 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 300×150/6.3 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 142.3 kN·m
Shear/ 568.9 kN
Compression/ —

The compression check is not available: in uniform compression the section is class 4 and effective properties per EN 1993-1-5 are required. Bending and shear are unaffected.

Class1 / 4bending / compression
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl142.3 kN·m / 88.2 kN·m
Vc,z,Rd / Vc,y,RdA_v = 3583 mm²568.9 kN / 284.5 kN
Npl,Rd / Nb,Rd— / —
Ncr,y / Ncr,z5.19 MN / 1.78 MN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.59

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.