RHS · EN 10219 · cold formed

RHS 300×100/12

RHS 300×100/12 is a cold-formed rectangular hollow section per EN 10219: height 300 mm, width 100 mm, wall thickness 12 mm, weight 66 kg/m, cross-section area 84.1 cm², moment of inertia Iy = 7808 cm⁴, elastic section modulus Wel,y = 520.6 cm³.

Cross section · mm
yz10030012[mm]
300Height h · mm
100Width b · mm
84.06Area A · cm²
66.00Mass G · kg/m
Geometry
Height h300.00 mm
Width b100.00 mm
Wall thickness t12.00 mm
Outer corner radius ro36.00 mm
Inner corner radius ri24.00 mm
Cross-section area A84.060 cm²
Weight G
steel 7850 kg/m³
66.00kg/m
Section properties
I7 808.000 cm⁴1 343.000 cm⁴
Wel520.600 cm³268.600 cm³
Wpl710.300 cm³320.900 cm³
It4 177.000 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 300×100/12 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 195.3 kN·m
Shear/ 1.00 MN
Compression/ 773.2 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl195.3 kN·m / 88.2 kN·m
Vc,z,Rd / Vc,y,RdA_v = 6305 mm²1.00 MN / 333.7 kN
Npl,Rd / Nb,Rd2.31 MN / 773.2 kN
Ncr,y / Ncr,z6.47 MN / 1.11 MN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.33

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.