RHS · EN 10219 · cold formed

RHS 180×100/6.3

RHS 180×100/6.3 is a cold-formed rectangular hollow section per EN 10219: height 180 mm, width 100 mm, wall thickness 6.3 mm, weight 25.4 kg/m, cross-section area 32.3 cm², moment of inertia Iy = 1335 cm⁴, elastic section modulus Wel,y = 148.3 cm³.

Cross section · mm
yz1001806.3[mm]
180Height h · mm
100Width b · mm
32.33Area A · cm²
25.40Mass G · kg/m
Geometry
Height h180.00 mm
Width b100.00 mm
Wall thickness t6.30 mm
Outer corner radius ro15.75 mm
Inner corner radius ri9.45 mm
Cross-section area A32.330 cm²
Weight G
steel 7850 kg/m³
25.40kg/m
Section properties
I1 335.000 cm⁴535.800 cm⁴
Wel148.300 cm³107.200 cm³
Wpl185.500 cm³123.600 cm³
It1 283.000 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 180×100/6.3 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 51.0 kN·m
Shear/ 330.0 kN
Compression/ 305.7 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl51.0 kN·m / 34.0 kN·m
Vc,z,Rd / Vc,y,RdA_v = 2078 mm²330.0 kN / 183.3 kN
Npl,Rd / Nb,Rd889.1 kN / 305.7 kN
Ncr,y / Ncr,z1.11 MN / 444.2 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.34

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.