RHS · EN 10219 · cold formed

RHS 100×50/3

RHS 100×50/3 is a cold-formed rectangular hollow section per EN 10219: height 100 mm, width 50 mm, wall thickness 3 mm, weight 6.6 kg/m, cross-section area 8.4 cm², moment of inertia Iy = 106.5 cm⁴, elastic section modulus Wel,y = 21.3 cm³.

Cross section · mm
yz501003[mm]
100Height h · mm
50Width b · mm
8.41Area A · cm²
6.60Mass G · kg/m
Geometry
Height h100.00 mm
Width b50.00 mm
Wall thickness t3.00 mm
Outer corner radius ro6.00 mm
Inner corner radius ri3.00 mm
Cross-section area A8.410 cm²
Weight G
steel 7850 kg/m³
6.60kg/m
Section properties
I106.500 cm⁴36.060 cm⁴
Wel21.290 cm³14.420 cm³
Wpl26.660 cm³16.440 cm³
It88.560 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 100×50/3 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 7.3 kN·m
Shear/ 89.0 kN
Compression/ 25.3 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl7.3 kN·m / 4.5 kN·m
Vc,z,Rd / Vc,y,RdA_v = 561 mm²89.0 kN / 44.5 kN
Npl,Rd / Nb,Rd231.3 kN / 25.3 kN
Ncr,y / Ncr,z88.3 kN / 29.9 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.11

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.