RHS · EN 10219 · cold formed

RHS 100×40/5

RHS 100×40/5 is a cold-formed rectangular hollow section per EN 10219: height 100 mm, width 40 mm, wall thickness 5 mm, weight 9.7 kg/m, cross-section area 12.4 cm², moment of inertia Iy = 135.6 cm⁴, elastic section modulus Wel,y = 27.1 cm³.

Cross section · mm
yz401005[mm]
100Height h · mm
40Width b · mm
12.36Area A · cm²
9.70Mass G · kg/m
Geometry
Height h100.00 mm
Width b40.00 mm
Wall thickness t5.00 mm
Outer corner radius ro10.00 mm
Inner corner radius ri5.00 mm
Cross-section area A12.360 cm²
Weight G
steel 7850 kg/m³
9.70kg/m
Section properties
I135.600 cm⁴30.760 cm⁴
Wel27.120 cm³15.380 cm³
Wpl36.090 cm³18.520 cm³
It87.920 cm⁴
Reference
Profile standardEN 10219
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of RHS 100×40/5 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ 9.9 kN·m
Shear/ 140.2 kN
Compression/ 22.5 kN
Class1
Resistances and factors
Mc,y,Rd / Mc,z,RdW_pl9.9 kN·m / 5.1 kN·m
Vc,z,Rd / Vc,y,RdA_v = 883 mm²140.2 kN / 56.1 kN
Npl,Rd / Nb,Rd339.9 kN / 22.5 kN
Ncr,y / Ncr,z112.4 kN / 25.5 kN
fyEN 10219-1275 MPa
γM0 / γM11.00 / 1.00
Curve c · χ0.07

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.