L · EN 10056-1

L 200×200/16

L 200×200/16 is an equal-leg steel angle per EN 10056-1: leg length 200 mm, thickness 16 mm, weight 48.5 kg/m, cross-section area 61.8 cm², moment of inertia Iy = 2341 cm⁴, elastic section modulus Wel,y = 161.7 cm³.

Cross section · mm
yzuvα2002001655.2144.8144.855.2[mm]
200Leg a · mm
16Thickness t · mm
61.80Area A · cm²
48.50Mass G · kg/m
Geometry
Leg length a200.00 mm
Thickness t16.00 mm
Cross-section area A61.800 cm²
Centroid Cx=Cy55.2 mm
Weight G
steel 7850 kg/m³
48.50kg/m
Section properties
Moment of inertia Iy=Iz2 341.000 cm⁴
Section modulus Wel161.671 cm³
Plastic modulus Wpl293.470 cm³
Radius of gyration iy61.60 mm
Principal axes u–v
Iu3 725.000 cm⁴
Iv957.200 cm⁴
Reference
Profile standardEN 10056-1
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of L 200×200/16 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ —
Shear/ 490.6 kN
Compression/ —

Bending and compression are not available for class 4 sections; effective properties per EN 1993-1-5 are required.

Class4
Resistances and factors
Mc,y,Rd / Mc,z,Rd— / —
Vc,z,Rd / Vc,y,RdA_v = 3090 mm²490.6 kN / 490.6 kN
Npl,Rd / Nb,Rd— / —
Ncr,y / Ncr,v1.94 MN / 793.6 kN
fyEN 10025-2275 MPa
γM0 / γM11.00 / 1.00
Curve b · χ0.36

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.

For angles the bending values refer to the axes parallel to the legs, which are not principal axes. A moment about one of them also bends the section about the other, so bending has to be resolved into the principal axes u and v and checked biaxially. Buckling already uses the weaker principal axis v.