L · EN 10056-1

L 150×150/13

L 150×150/13 is an equal-leg steel angle per EN 10056-1: leg length 150 mm, thickness 13 mm, weight 29.5 kg/m, cross-section area 37.6 cm², moment of inertia Iy = 791.7 cm⁴, elastic section modulus Wel,y = 73 cm³.

Cross section · mm
yzuvα1501501341.6108.4108.441.6[mm]
150Leg a · mm
13Thickness t · mm
37.60Area A · cm²
29.50Mass G · kg/m
Geometry
Leg length a150.00 mm
Thickness t13.00 mm
Cross-section area A37.600 cm²
Centroid Cx=Cy41.6 mm
Weight G
steel 7850 kg/m³
29.50kg/m
Section properties
Moment of inertia Iy=Iz791.700 cm⁴
Section modulus Wel73.035 cm³
Plastic modulus Wpl132.960 cm³
Radius of gyration iy45.90 mm
Principal axes u–v
Iu1 259.000 cm⁴
Iv324.600 cm⁴
Reference
Profile standardEN 10056-1
EurocodeEN 1993-1-1 (EC3)

Check to EN 1993-1-1

Work out the utilisation of L 150×150/13 for your design forces

Enter the design loads and the section is checked for bending, shear and compression with flexural buckling.

Bending/ —
Shear/ 298.5 kN
Compression/ —

Bending and compression are not available for class 4 sections; effective properties per EN 1993-1-5 are required.

Class4
Resistances and factors
Mc,y,Rd / Mc,z,Rd— / —
Vc,z,Rd / Vc,y,RdA_v = 1880 mm²298.5 kN / 298.5 kN
Npl,Rd / Nb,Rd— / —
Ncr,y / Ncr,v656.4 kN / 269.1 kN
fyEN 10025-2275 MPa
γM0 / γM11.00 / 1.00
Curve b · χ0.22

Yield strength is taken from the product standard for the governing thickness, so above 16 mm it is lower than the nominal grade. Simplified checks per EN 1993-1-1, without M+N+V interaction, without lateral-torsional buckling and without web shear buckling. Verify with a full design.

For angles the bending values refer to the axes parallel to the legs, which are not principal axes. A moment about one of them also bends the section about the other, so bending has to be resolved into the principal axes u and v and checked biaxially. Buckling already uses the weaker principal axis v.